Int J Prosthodont 32 (2019), No. 4 15. July 2019
Int J Prosthodont 32 (2019), No. 4 (15.07.2019)
Page 364-366, doi:10.11607/ijp.5985, PubMed:31283817
Marginal Adaptation of Monolithic High-Translucency Versus Porcelain-Veneered Zirconia Crowns
Rayyan, Mohammad R.
Purpose: To compare the marginal adaptation of monolithic high-translucency zirconia crowns and porcelain-veneered zirconia crowns. Materials and Methods: A master die was scanned to design and produce 10 porcelain-veneered zirconia copings for layering (PVZ group) and 10 monolithic high-translucency zirconia crowns (HTZ group). The mean vertical marginal gap in both groups was measured from eight predetermined points using a digital microscope. Results: The mean marginal gap in the PVZ group (39.62 ± 18.98 μm) was significantly higher than in the HTZ group (23.54 ± 7.57 μm) (P < .05). Conclusion: High-translucency monolithic zirconia crowns had better marginal fit than porcelain-veneered zirconia crowns. Both groups exhibited clinically acceptable marginal discrepancies.
|